Error:
Deviation of seconds between qRFC counter and current time
Scenario:
While trying to perform Init with data transfer, the
process is getting terminated with the below error message.
Deviation
of 1,431 seconds between qRFC counter 000012983760510000060000 and current time
22.02.2011 RSQU 101
Deviation
of 172 seconds between qRFC counter 000013619012840000010000 and current time
26.02.2013 17:51:52
Cause:
The error caused because of the time difference between the
Application serve of Source system and DS server of source system.
Also time difference between BW system and ECC system.
Solution:
To synch the times between the server and systems , just run
the report Program :RSDBTIME. This program will check the time Inconsistencies between ECC
n BW systems.