1. go to ALRTCATDEF
2. select classification "Process Chains"
3. click on display/change
4. double-click on "error in a process of a process chain"
5. click on "fixed recipients"
6. write in your username (you have to maintain your e-mail address in SU01 for that to work)
7. save
8. go to your process chain (rspc)
9. go into edit mode
10. from the menu, select Process chain -> attributes -> alerting
11. check "send alerts if errors occur"
- Steps 1 to 7 should be done once to configure.
- Follow steps 8 to 10 for the process chains for which alert emails are required.

1 comments:
Good Effort..., Thanks a lot yaar...
Post a Comment